Structure
And Preponderance
The stepping clutch operation theory is that when power off, the
stopper will be locked.
The control method is simple as the normal magnet clutch.
- Compact, high torque
Compact with friction clutch,higher torque can be gained.
- High operation movement accuracy,
Due to the design of the mechanism construction, the stopper
will be locked when power off, so, high accurate mechanical
movement, reliability can be gained.
Methods Of Selection
To choose suitable Flat-Pack clutch, please determine followings:
- TORQUE
Besides load, it's necessary to also consider variation of temperature
and voltage. Therefore, please time load by safety coefficient
1.3X.
- DUTY CYCLE
Besides on time and off time, please also max. on time.
- OPERATION VOLTAGE
To define coil input DC voltage.
General Characteristics
Insulation class:
E CLASS. (120°C)
Dielectric strength:
AC 1000V, 50/60Hz, 1min. (at normal temperature and normal humidity)
Insulation resistance:
more than 50MO on a DC 500V (at normal temperature and normal humidity)
Life:
to define required life
Order Issuing
When order issuing, please define following 2 points.
TYPE NO. |
LIFE |
STC |
- |
CL |
F |
15 |
A |
R |
- |
01 |
|
|
|
|
|
|
|
|
|
|
500,000 |
- SOLEN
- CLUTCH
- ROTOR DIAMETER
- MODEL
- C: CLOSE TYPE or O: OPEN TYPE
- ROTATE DIRECTION (R: CW or L: CCW)
- SERIES NO.
|